Finger Protection
Typical IFM guidance uses 14 mm resolution where finger detection is required. The actual safety distance must be calculated for the machine.
Use non-contact optoelectronic protection where operators need access to a hazardous area without a physical guard blocking the opening. Selection must account for required safety level, resolution, protected height, range, machine stopping time and safety distance.

Light curtains use closely spaced beams for finger/hand/body-part protection; light grids use fewer, more widely spaced beams for body access protection.
Typical IFM guidance uses 14 mm resolution where finger detection is required. The actual safety distance must be calculated for the machine.
30 mm resolution is a common IFM route for hand protection where the application and calculated safety distance permit it.
Two-, three- or four-beam light grids are used for body access detection, with beam spacing and protected height selected for the application.
Light curtains are effective only when bypassing or reaching around the protective field is prevented by the complete machine design.
Access prevention or perimeter guarding around automated cells and work areas.
Protect operator access while allowing material handling; floating blanking may be relevant for defined feed processes.
Protect open access points where a physical guard would obstruct normal material or operator flow.
Muting can temporarily bypass the safety function for authorised material passage when the complete muting architecture is correctly engineered.
Current IFM global pages include Type 2/SIL 1 and Type 4/SIL 3 routes; exact availability must be checked for the selected regional product range.
| Protection need | Typical IFM route | Resolution / beam spacing | Engineering checks |
|---|---|---|---|
| Finger detection | Safety light curtain | 14 mm typical | Stop time, safety distance, protected height, range |
| Hand detection | Safety light curtain | 30 mm typical | Reach-through risk, safety distance, machine cycle |
| Body / perimeter access | Safety light grid | 2/3/4 beams; 500/400/300 mm spacing routes | Access path, bypass routes, range |
| Material transfer | Muting architecture | Application dependent | Muting sensors, sequence, timing, feedback, restart |
| Material present in field | Blanking route | Application dependent | Permitted beams, object geometry, residual protection |
A transmitter and receiver create multiple infrared beams. Interruption causes the safety outputs to change state so the machine safety system can stop or prevent hazardous motion. The required distance from the hazard depends on stopping performance and application geometry.
The exact OY variant follows from the machine safety function and geometry.