ifm · Condition Monitoring

ifm VTV Vibration Transmitters

Simple, continuous overall-vibration trending via a standard 4–20 mA signal. VTV is a practical retrofit route when the PLC, frequency converter or monitoring system already has an analogue input and detailed vibration diagnostics are not required at the sensor.

4–20 mAv-RMS10–1,000 Hz1 measurement axisISO 20816 route
ifm VTV12A vibration transmitter
Signal4–20 mAContinuous analogue vibration trend
Measured valuev-RMSOverall vibration velocity
Frequency10–1,000 HzCurrent VTV family selection range
Harsh environmentUp to 125 °CSelected versions; verify exact model
Straightforward machine trending

VTV for controller-based monitoring

The transmitter converts overall vibration severity into a standard analogue signal. That keeps the field device simple and puts warning, alarm and trend logic in the PLC, frequency converter or monitoring system.

Motors

Trend rising overall vibration caused by developing unbalance, misalignment or mechanical looseness on suitable constant-speed rotating equipment.

Pumps & fans

Use the analogue trend to detect gradual deterioration before machine vibration reaches unacceptable levels.

Retrofit installations

Useful where an existing analogue input is already available and adding IO-Link or separate diagnostic electronics would add unnecessary complexity.

Important: VTV is an overall-vibration transmitter, not a frequency-selective diagnostic system. It is best for trending severity—not for locating a specific bearing fault frequency or performing root-cause analysis.
ifm VTV122 vibration transmitter
Simple architecture

Vibration severity directly into the PLC or drive

VTV continuously outputs the RMS vibration velocity as a 4–20 mA signal. The analogue value can be scaled, trended and alarmed in a suitable control or monitoring system.

MachineMotor / pump / fan
TransmitterVTV
Signal4–20 mA
ControlPLC / VFD / monitor
Easy retrofitStandard analogue current signal requires no dedicated IO-Link network.
Controller-owned limitsWarning and alarm thresholds can be managed in the customer control architecture.
Current VTV routes

Select measuring range and environmental variant

ifm VTV122 vibration transmitter
VTV122

0…25 mm/s

Standard current VTV route for general vibration severity monitoring.

  • 10…1,000 Hz
  • 1 × 4–20 mA
  • Set-screw mounting
  • Selected version data: -30…125 °C, IP67/IP68/IP69K
ifm VTV121 vibration transmitter
VTV121

0…50 mm/s

Higher overall-vibration range for applications where 25 mm/s full-scale is insufficient.

  • 10…1,000 Hz family route
  • 1 × 4–20 mA
  • Verify exact environmental data before selection
ifm VTV12A hazardous-area vibration transmitter
VTV12A

Hazardous-area version

VTV variant for applications requiring the documented ATEX II 3D / II 3G route.

  • 0…25 mm/s
  • 10…1,000 Hz
  • 4–20 mA
  • Confirm zone and complete approval conditions
Technical overview

Key VTV family data

Overall vibration is intentionally simple.

VTV is well suited to trending machine vibration severity when the host controller performs the alarm logic. If the requirement includes multi-axis condition indicators, bearing analysis or frequency-selective monitoring, review another ifm platform.

Measured quantityRMS vibration velocity (v-RMS)
Analogue output4…20 mA
Frequency range10…1,000 Hz
Measuring range0…25 mm/s or 0…50 mm/s by model
Measurement axes1
MountingSet screw; exact thread / supplied hardware by model
Selected VTV122 environment-30…125 °C; IP67 / IP68 / IP69K
Choose the right depth

VTV, VVB or VSE?

NeedRouteReason
One simple continuous overall-vibration valueVTV Best fitSimple 4–20 mA integration and controller-side trending.
Smart sensor with multiple condition indicators and IO-LinkVVB / VVB3Local condition processing, temperature and richer machine-health data.
Multiple accelerometers, frequency-selective diagnosis, complex machineryVSEProgrammable edge diagnostics in time and frequency domains.
Requirement capture

To confirm before selecting VTV

Machine & rpmMachine type, shaft speed and whether speed varies significantly.
Expected vibration rangeChoose 25 or 50 mm/s full-scale based on the machine and alarm philosophy.
Analogue inputAvailable 4–20 mA PLC, VFD or monitoring input and scaling.
EnvironmentTemperature, washdown and IP requirement.
Hazardous areaZone/classification and approval requirements if VTV12A is considered.
Monitoring goalOverall trend only or need for fault-specific diagnostic information.