Cables and connectors
Cable, connector and adapter accessories are selected with the switch, based on the run length and the connection method at the controller.
Guard monitoring built into the hinge itself. Because the switch sits at the pivot and is concealed within the guard, there is no exposed actuator on the leading edge to align, damage or defeat — while the switching point remains adjustable anywhere from 0° to 270°.
The advantages come directly from where the switch sits, not from generic product claims.
Mounted within the guard, so there is no visible switch or actuator inviting manipulation.
Set anywhere from 0° to 270° and re-adjustable, so the trip angle suits the guard rather than the reverse.
Supplied as a complete solution, removing the separate alignment of a switch and actuator pair.
Rated for heavy soiling and hygiene-critical areas where exposed switches struggle.
The manufacturer lists packaging technology, the pharmaceutical industry and the food industry among its typical industry uses.
Rotatable and hinged gates where the monitoring point is better placed at the pivot than on the closing edge.
Flaps and covers that open through a wide arc, where a conventional actuator would disengage early or bind.
Food and pharmaceutical machinery cleaned regularly, where IP67 and a concealed installation both matter.
Access points where an exposed switch has previously been bypassed with a spare actuator.
The values below are the ones that decide whether PSENhinge suits a given guard. Complete specifications, approvals and dimensions belong to the selected order number in current manufacturer documentation.
| Function | Monitoring the position of movable guards in accordance with EN 60947-5-3 |
|---|---|
| Performance level | Up to PL e of EN ISO 13849-1 if two switches are used |
| Safety integrity level | Up to SIL CL 3 of EN/IEC 62061 if two switches are used |
| Switching point | Freely settable from 0° to 270°, and re-adjustable |
| Contacts | 2 NC |
| Protection type | IP67 |
| Housing | Plastic-bodied design |
| Mounting | Systems can be attached on the right and on the left |
| Controller pairing | Can be used with controllers for applications with high safety requirements |
| Guard types | Rotatable and hinged gates, and flaps |
The range allows the hinge switch to be fitted to either side of the guard. Confirm the exact order number against current manufacturer data for the guard in question.
Systems can be attached to the right and left, so the guard swing direction does not dictate a different product family.
The trip angle is set during installation and can be re-adjusted later if the guard or the process changes.
The manufacturer lists the required cable, connector and adapter accessories under connection technology for this family.
Cable, connector and adapter accessories are selected with the switch, based on the run length and the connection method at the controller.
The switch provides the guard signal; a safety relay or configurable controller performs the safe evaluation and drives the output stage.
Where several guards are wired in series, the effect on fault detection and on the achievable performance level must be assessed for the arrangement.
PSENhinge is a mechanical fit as much as an electrical one. These points determine whether it suits the guard and which variant is required.
The hinge switch reports guard position. If the hazard continues after the stop command, position monitoring alone is not sufficient and a locking device is required instead.