Modular safety relay

myPNOZ

Between a single relay and a configurable controller sits a gap: several safety functions that interact, but not enough to justify programming. myPNOZ fills it — a modular relay assembled to your specific combination of functions and produced individually in batch size 1, configured in a browser rather than in an engineering tool.

Batch size 1, built to requirement2 to 30 safe input functionsModular, expandableConfigured without programmingmyPNOZ Creator online tool
2–30Safe input functions
Batch size 1Individually produced
12.5 / 17.5 mmModule widths
Pilz myPNOZ modular safety relay assembly with head and expansion modules
myPNOZAssembly shown; the module set is defined by the function list
2–30Safe input functions covered
Batch size 1Produced individually
CreatorBrowser-based configuration
ModularAdapt and expand
Why it is specified

Effect of the modular approach

The value is in matching the device to the function list exactly, without either wiring several relays together or moving to a programmed controller.

Built to the function list

Produced individually in batch size 1, tailor-made to the stated requirements.

Wide application range

From a small application with just two safe input functions to larger applications with up to 30 input functions.

Configured, not programmed

The myPNOZ Creator defines the assembly online, so no engineering software or programming skill is required.

Adaptable over life

The modular design means the relay is flexible to adapt and expand at all times.

Applications

myPNOZ is used

The manufacturer states the modular relay covers a wide range of applications and can be used on almost any automated plant.

Guarded production machinery with multiple monitored access points
Multiple guards

Several access points on one machine

Machines with several guards, stops and enabling positions, where each function must be evaluated but the logic between them stays simple.

ConfirmConfirm the complete function list.
Emergency stop and safety door devices on existing machinery
Relay consolidation

Replacing a wall of relays

Existing panels where functions were added one relay at a time until the wiring became difficult to follow or to modify.

ConfirmConfirm existing devices and circuits.
Pilz myPNOZ modular safety relay assembly
Series machinery

Repeatable machine builds

A defined function combination repeated across a machine range, where the same assembly can be ordered again reliably.

ConfirmConfirm the standard function set and quantity.
Technical data

Selection parameters that matter

myPNOZ is specified by its function list rather than by a single part number. These are the parameters that shape the assembly.

Because the device is built to order, the function list must be complete and correct before the assembly is defined.
ConceptModular safety relay produced individually in batch size 1, tailor-made to requirements
Application rangeFrom two safe input functions up to 30 input functions
ConfigurationDefined in the myPNOZ Creator online tool
ProgrammingNo programming required — the assembly is configured
Module widthsModules from 12.5 mm and 17.5 mm
FlexibilityModular design allows the relay to be adapted and expanded
ScopeCovers a wide range of applications on almost any automated plant
OrderingThe configured assembly is ordered as a defined build
The combination logic is fixed by the assembly. Where functions must be changed frequently, or where diagnostics and communication are required, review PNOZmulti 2 instead.
Models

Assembly definition

The build is decided by the function list, so the specification work happens before the order rather than after it.

Scale

2 to 30 input functions

The number of safe input functions is the primary sizing parameter for the assembly.

Minimum
2 functions
Maximum
30 functions
Modules

12.5 and 17.5 mm

Module widths determine the overall width in the panel once the function list is fixed.

Widths
12.5 / 17.5 mm
Type
Modular
Configuration

myPNOZ Creator

The online tool defines the module set and the combination logic without engineering software.

Tool
Browser-based
Skill
No programming
Lifecycle

Adapt and expand

The modular design allows the assembly to be adapted as the machine changes.

Change
Modular
Reorder
Defined build
Accessories

Configuration and integration

The main dependency is the function list; beyond that, the relay integrates like any other evaluation device.

Configuration

myPNOZ Creator

The online tool used to define the assembly, the module set and the combination logic before ordering.

ConfirmConfirm the complete function list first.
Input devices

Guards, stops and protective devices

The relay evaluates the same input devices as any PNOZ relay; the function list determines the module set.

ConfirmConfirm device types and channel arrangement.
Output stage

Contactors and stopping elements

Safe outputs drive the machine stopping element, with feedback loop monitoring where required.

ConfirmConfirm the stopping element and load.
Before quotation

Application review

Because the device is built to order, the function list carries the whole specification. Getting it complete is the main task.

Function list

  • Every safety function to be evaluated, with its input device
  • How many safe input functions in total
  • Which functions interact, and how
  • Required performance or integrity level, if determined

Inputs

  • Type of each input device and its output arrangement
  • Single or dual channel per function
  • Whether any devices are connected in series
  • Cable lengths and connection method

Outputs

  • Number of safe outputs required
  • Stopping element for each output group
  • Whether feedback loop monitoring is required
  • Required stop category per function

Panel and lifecycle

  • Available panel width for the assembly
  • Supply voltage
  • Expected future changes to the machine
  • Quantity and repeat-order requirement
Related technologies

myPNOZ sits in the architecture

It occupies the middle ground: more capable than a single relay, simpler than a configurable controller. The boundary is usually diagnostics and the expectation of change.

PNOZ X or PNOZcompact for one function
PNOZsigma for compact single functions
PNOZmulti 2 when diagnostics are needed
Guard switches and E-STOP devices
Light curtains and area protection
Contactors with feedback loop
Pilz myPNOZ modular safety relay assembly