Adapters and cables
A range of adapters and cables is available for the locking device; the selection follows the run length and the controller connection.
Safety gate monitoring combined with electromagnetic process guarding. Where opening a guard mid-cycle would spoil the process rather than expose a person to run-down, PSENslock 2 holds the guard closed and monitors its position, on swing gates, sliding gates, covers and flaps.
The device combines guard position monitoring with electromagnetic holding, and adds configuration options that matter in practice on real doors.
Holding force F1max of optionally 1,000 or 2,000 N keeps the guard closed through the cycle.
Latching force is adapted to the door through the Config Key, rather than being fixed at manufacture.
A version is available whose OSSDs switch independently of the guard locking status, adding flexibility in the control design.
Four LEDs on both sides give direct status indication regardless of mounting orientation.
The manufacturer states the device safeguards swing gates and sliding gates, as well as covers and flaps.
Cell access doors where the guard must stay closed for the duration of the production cycle.
Inspection covers and hoppers where an opened flap would interrupt or contaminate the process.
Machines where unnecessary interruptions are the actual problem, rather than a hazardous run-down.
Applications needing efficient guard locking where conditions are demanding, at IP67.
These are the values that decide the variant. Complete specifications, approvals and dimensions belong to the selected order number in current manufacturer documentation.
| Function | Safety gate monitoring with electromagnetic process guarding |
|---|---|
| Guard types | Swing gates, sliding gates, covers and flaps |
| Holding force | F1max, optionally 1,000 N or 2,000 N |
| Latching force | Adjustable via the Config Key |
| Performance level | PL e and PL d application routes listed by |
| Protection type | IP67 |
| Diagnostics | 4 LEDs on both sides for direct status indication |
| Output option | Version whose safety outputs (OSSDs) switch independently of guard locking status |
Three choices normally define the order: holding force, output behaviour and connection arrangement.
Selected from the door mass, the force a person might apply and the process-protection requirement.
Safety outputs switch independently of the guard locking status, allowing the locking and the safety signal to be handled separately in the control design.
Latching force is adapted to individual requirements on site rather than fixed by the ordered variant.
Accessories are listed by as tailored to both PSENslock and PSENslock 2; confirm which generation an existing installation uses.
The manufacturer lists dedicated accessories for safety gate monitoring alongside this family, plus a range of adapters and cables.
A range of adapters and cables is available for the locking device; the selection follows the run length and the controller connection.
Used to adapt the latching force to the individual door, so the guard holds without being difficult to operate.
Commonly combined with a gate operating unit for local commands and a controller for the safe evaluation.
The first question is whether process guarding is genuinely sufficient, or whether the hazard requires personnel-protection locking.