Adjustment at reduced speed
Threading, format change and adjustment need the machine to move while someone is close to it, at a speed proven to be within the safe limit.
Switching off is not always the safest response. Where an operator must observe, thread or adjust while a machine moves, the movement itself has to be monitored — and PNOZ s30 does that independently of the drive, which is what makes it work on retrofits and mixed drive brands.
The device watches the drive rather than trusting it, which is exactly what is needed when the drive itself offers no rated safe function.
A stand-alone monitor suits retrofits, mixed drive brands and drives without rated safe functions.
Parameter entry and diagnostics via an illuminated display, or configuration with the PNOZsigma Configurator.
The manufacturer lists advance warning of shutdown when a defined threshold is reached, so production can react before the stop.
Safety functions implemented in accordance with EN 61800-5-2, using the recognised function names.
Speed and standstill monitoring is normally introduced to allow controlled access, rather than to add another way of stopping the machine.

Threading, format change and adjustment need the machine to move while someone is close to it, at a speed proven to be within the safe limit.

Rather than releasing a guard on a timer, the guard stays locked until standstill is actually monitored, which removes the guesswork from long run-down.

Where the hazard exists in one direction, monitoring direction of rotation allows productive movement while the dangerous direction stays blocked.
These are the values that decide whether the monitor suits the drive and the application. Feedback compatibility must be confirmed for the specific installation.
| Monitored quantities | Speed, standstill, position and direction of rotation |
|---|---|
| Additional monitoring | Speed range monitoring and broken shear pin monitoring on drives |
| Performance level | EN ISO 13849-1 up to PL e |
| Integrity level | EN IEC 62061 up to SIL CL 3 |
| Safety functions | Implemented in accordance with EN 61800-5-2 |
| Safe speed range (SSR) | Combination of Safely limited speed (SLS) and Safe speed monitor (SSM) |
| Configuration | PNOZsigma Configurator, or directly on the device via the illuminated display |
| Diagnostics | Parameter entry and diagnostic messages shown on the illuminated display |
| Contact expansion | PNOZ s22 |
| Further functions | Advance warning of shutdown at a defined threshold; auto reset when switching parameter sets; synchronous start for all outputs; non-retriggerable off delay time |
| Lifts | Can be used in lifts in accordance with EN 81-20 / EN 81-50 |
The device is configured rather than ordered in variants, so the decisions are about function, feedback and outputs.
Speed, standstill, position, direction or speed range — selected from what the application actually requires.
Parameters can be entered on the illuminated display, or the device configured with the PNOZsigma Configurator.
Contact expansion where more output contacts are required than the monitor itself provides.
The manufacturer states the device can be used in lifts in accordance with EN 81-20 and EN 81-50.
A speed monitor is never specified alone — the feedback system and what the output interlocks are both part of the decision.
The monitor requires a feedback system; type, resolution, signal and cabling must be compatible and diagnostically adequate.
Adds output contacts where the monitor alone does not provide enough for the stopping elements involved.
Standstill monitoring is commonly interlocked with guard locking so the guard releases on proven standstill rather than a timer.
Safe motion depends on mechanical facts as much as electrical ones. Without these the function cannot be sized or validated.
Feedback, evaluation, the drive response and any mechanical brake all sit inside the safety function. The calculated reaction time must include every one of them.