Multi-guard machines
Several guards, stops and enabling positions on one machine, where each must be evaluated and the maintenance team needs to see which device tripped.
Once a machine carries several safety functions that interact, need diagnostics, or are likely to change, a configurable safe controller replaces an expanding set of wired relays. The decision between a small controller and a full automation system depends on the scale of the plant and how far the I/O is distributed.
PNOZmulti 2 and PSS 4000 are not interchangeable. One is a configurable small controller for machine safety; the other is an automation system covering safety and standard control across a plant.
The manufacturer describes the configurable safe small controllers PNOZmulti 2 as used in virtually every area of plant and mechanical engineering, monitoring safety functions safely while also performing standard control functions economically.
An automation system rather than a safety add-on: The manufacturer positions PSS 4000 as covering safety and automation together for plant and machinery.
The honest dividing line is whether the safety functions belong to one machine, or to a plant of interconnected stations.
| Criterion | Stay with safety relays | PNOZmulti 2 | PSS 4000 |
|---|---|---|---|
| Number of safety functions | One to a few, independent | Several, interacting | Many, across stations |
| Scope | Single function | Machine or cell | Plant or line |
| Expansion | Add a device per function | Expansion modules on the base unit | Distributed system nodes |
| Distributed I/O | Not applicable | Available via modules | Core capability |
| Standard control | Separate PLC | Standard functions performed economically | Safety and standard in one system |
| Communication | Diagnostic contacts | Fieldbus and communication modules | SafetyNET p and fieldbus |
| Engineering approach | Wiring and device selection | Graphical configuration | Programming in PAS4000 |
| Change tolerance | Rewiring required | Reconfigure and revalidate | Reprogramme and revalidate |
The common trigger is not a single complex function, but the accumulation of ordinary ones.
Several guards, stops and enabling positions on one machine, where each must be evaluated and the maintenance team needs to see which device tripped.
Where safety functions span several stations and I/O sits away from the panel, a distributed automation system avoids long safe wiring runs.
Several protective devices around one cell, needing coordinated evaluation, muting where applicable, and a single clear reset arrangement.
A base unit cannot be chosen without the function list and the I/O count. These inputs size the controller and its expansion.
Sensors and command devices feed the controller; the controller evaluates and drives the safe outputs. Diagnostics can be shared with the standard control system without the standard system becoming part of the safety function.