Safe Control

Limits of wired relay logic

Once a machine carries several safety functions that interact, need diagnostics, or are likely to change, a configurable safe controller replaces an expanding set of wired relays. The decision between a small controller and a full automation system depends on the scale of the plant and how far the I/O is distributed.

Multiple safety functions Configured, not hard-wired Diagnostics and expansion PNOZmulti 2 · PSS 4000
PL ePNOZmulti 2 capability
SIL CL 3PNOZmulti 2 capability
Safety + standardBoth function types
Pilz PNOZmulti 2 configurable safety controller base units
PNOZmulti 2Base units shown; expansion follows the application
PL ePNOZmulti 2
SIL CL 3PNOZmulti 2
ConfiguratorPNOZmulti Configurator tool
DistributedPSS 4000 with SafetyNET p
Architecture selection

Decide the scale before the product

The honest dividing line is whether the safety functions belong to one machine, or to a plant of interconnected stations.

CriterionStay with safety relaysPNOZmulti 2PSS 4000
Number of safety functionsOne to a few, independentSeveral, interactingMany, across stations
ScopeSingle functionMachine or cellPlant or line
ExpansionAdd a device per functionExpansion modules on the base unitDistributed system nodes
Distributed I/ONot applicableAvailable via modulesCore capability
Standard controlSeparate PLCStandard functions performed economicallySafety and standard in one system
CommunicationDiagnostic contactsFieldbus and communication modulesSafetyNET p and fieldbus
Engineering approachWiring and device selectionGraphical configurationProgramming in PAS4000
Change toleranceRewiring requiredReconfigure and revalidateReprogramme and revalidate
Configuration is still a safety activity. Changing a configuration is faster than rewiring, but the modified safety function must be verified and validated again, and the project version controlled, before the machine returns to production.
Applications

Configurable controller application scope

The common trigger is not a single complex function, but the accumulation of ordinary ones.

Packaging machine controlled by a Pilz PNOZmulti 2 configurable safety controller
Production machinery

Multi-guard machines

Several guards, stops and enabling positions on one machine, where each must be evaluated and the maintenance team needs to see which device tripped.

Typical routePNOZmulti 2 with safe I/O expansion.
Engineer configuring a Pilz PSS 4000 automation system project
Plant scale

Lines and distributed stations

Where safety functions span several stations and I/O sits away from the panel, a distributed automation system avoids long safe wiring runs.

Typical routePSS 4000 with distributed I/O and SafetyNET p.
Pilz PSENscan safety laser scanners connected in series to a PNOZmulti 2 safety controller
Protective devices

Multiple scanners or curtains

Several protective devices around one cell, needing coordinated evaluation, muting where applicable, and a single clear reset arrangement.

Typical routePSENscan or PSENopt II into PNOZmulti 2.
Before selection or quotation

Engineering prerequisites

A base unit cannot be chosen without the function list and the I/O count. These inputs size the controller and its expansion.

Function inventory

  • Every E-STOP, guard, light curtain, scanner and enabling device
  • Which functions interact, and which are independent
  • Operating modes and how they change the active functions
  • Target performance level or safety integrity level per function

I/O and zones

  • Safe input and safe output counts, with spare capacity
  • Whether standard I/O will also be handled by the controller
  • Machine zones and whether they stop independently
  • Distance from the panel to the field devices

Motion and communication

  • Whether speed, standstill or direction must be monitored
  • Fieldbus required for diagnostics, and to which controller
  • Whether any safe communication between systems is needed
  • Data required by the plant or maintenance systems

Project and lifecycle

  • Who configures, who approves and who may change the project
  • Version control and where the project archive is kept
  • Commissioning evidence and validation records required
  • Spares strategy and expected machine lifetime
Related systems

The controller sits between detection and the machine

Sensors and command devices feed the controller; the controller evaluates and drives the safe outputs. Diagnostics can be shared with the standard control system without the standard system becoming part of the safety function.

Guard switches and E-STOP devices
Light curtains, scanners and radar
Motion-monitoring modules
Safe outputs to contactors and drives
Fieldbus diagnostics to the standard PLC
Operating-mode and access systems
Series connection of Pilz safety laser scanners into a PNOZmulti 2 safety controller
Modernising an existing machine?Retrofit routes across the complete safety portfolio, including what can justifiably remain in place, are set out inMachine Safety Retrofit & Modernisation.