Configurable safe small controller

PNOZmulti 2

When a machine accumulates safety functions, wired relay logic stops being maintainable long before it stops being possible. PNOZmulti 2 replaces it with a configured controller that carries the safety functions and the standard control functions together, and tells the maintenance team which device actually tripped.

Configured, not programmedUp to PL e / SIL CL 3Illuminated display diagnosticsMax 4 expansion modulesFieldbus and communication modules
PL eEN ISO 13849-1
SIL CL 3IEC 62061
4Expansion modules maximum
Pilz PNOZmulti 2 configurable safety controller base units
PNOZmulti 2Base units shown; expansion follows the application
PL eDepending on application
SIL CL 3Depending on application
4 + 1 + 1Expansion, communication, fieldbus
DisplayIlluminated, with custom texts
Why it is specified

Configurable controller capabilities

The manufacturer positions the benefit as an exact match to the application through expansion modules, with diagnostics that shorten downtime.

Matched to the application

Tailor-made costs because of an exact match for the application, through the use of expansion modules.

Diagnostics on the device

An illuminated display shows error messages, supply voltage state, inputs and outputs, status, device information and individual customer texts.

Connects to common fieldbuses

Short downtimes and high plant availability through connection to all common fieldbus systems via corresponding modules.

Serviceable program memory

Exchangeable program memory and a diagnostic interface support replacement and fault-finding.

Applications

PNOZmulti 2 is used

The manufacturer lists the devices that can be connected to the base units, which is the practical measure of what the controller can take on.

Production machine controlled by a Pilz PNOZmulti 2 safety controller
Multi-function machines

Several interacting functions

Machines with multiple guards, stops and enabling positions where each must be evaluated and the interaction between them matters.

ConfirmConfirm the complete function list and I/O counts.
Pilz PSENscan scanners in series connection with a PNOZmulti 2 controller
Protective devices

Scanners and light curtains

Several protective devices around one cell needing coordinated evaluation, muting where applicable and a single clear reset.

ConfirmConfirm the number and type of protective devices.
Safe operating mode selection integrated with a Pilz safety controller
Access control

Permission as a controller input

Access permission via PITreader is listed among the devices connectable to the base units, so permission becomes part of the logic.

ConfirmConfirm roles and which functions permission gates.
Technical data

Selection parameters that matter

These are the parameters that size the controller. The base unit is chosen first, then the expansion to match the application.

The manufacturer states maximum safety depending on the application up to PL e of EN ISO 13849-1 and SIL CL 3 of IEC 62061.
FunctionConfigurable safe small controller for safety functions and standard control functions
Performance levelUp to PL e of EN ISO 13849-1, depending on the application
Integrity levelUp to SIL CL 3 of IEC 62061, depending on the application
ExpansionMax. 4 expansion modules connected on the left-hand side
CommunicationMax. 1 communication module and 1 fieldbus module
FieldbusConnection to all common fieldbus systems via corresponding modules
DisplayIlluminated display showing error messages, supply voltage state, inputs and outputs, status, device information and individual customer texts
TerminalsPlug-in connection terminals — choice of spring-loaded or screw terminals, available as accessories
Program memoryExchangeable
DiagnosticsDiagnostic interface provided
Connectable devicesE-STOP pushbuttons, safety gate limit switches and safety gate switches, light curtains, laser scanners, two-hand pushbuttons, operating mode selector switches, pressure-sensitive safety mats, sensors, and access permission PITreader
Configuration is a safety activity. A modified configuration must be verified and validated again, and the project version controlled, before the machine returns to production.
Models

Base unit and expansion

The order is always the same: choose the base unit, then add expansion within the stated limits.

Base unit

The starting point

frames the first question as which base unit is right for the application; expansion follows from it.

Selection
Application-led
Then
Expansion
Expansion I/O

Up to 4 modules

A maximum of four expansion modules can be connected on the left-hand side of the base unit.

Maximum
4 modules
Position
Left-hand side
Communication

1 + 1 modules

A maximum of one communication module and one fieldbus module may be added.

Communication
Max 1
Fieldbus
Max 1
Terminals

Spring or screw

Plug-in connection terminals are available as accessories in spring-loaded or screw versions.

Type
Plug-in
Options
Spring / screw
Accessories

Terminals, memory and configuration

Three accessory decisions recur on almost every PNOZmulti 2 project.

Terminals

Plug-in connection terminals

Available as accessories in spring-loaded or screw versions, so the panel build standard decides rather than the controller.

ConfirmConfirm the preferred termination standard.
Service

Exchangeable program memory

Allows a controller to be replaced without re-loading the project from an engineering PC.

ConfirmConfirm the spares and recovery arrangement.
Engineering

PNOZmulti Configurator

The configuration tool used to define the safety functions graphically rather than by programming.

ConfirmConfirm who configures and how versions are controlled.
Before quotation

Application review

A base unit cannot be chosen without the function list and the I/O count. These inputs size the controller and its expansion.

Function inventory

  • Every E-STOP, guard, light curtain, scanner and enabling device
  • Which functions interact and which are independent
  • Operating modes and how they change the active functions
  • Target performance or integrity level per function

I/O and zones

  • Safe input and safe output counts, with spare capacity
  • Whether standard I/O will also be handled
  • Machine zones and whether they stop independently
  • Distance from the panel to the field devices

Communication

  • Which fieldbus is required, and to which controller
  • Whether a communication module is needed
  • Diagnostics expected by the standard control system
  • Whether access permission forms an input

Project and lifecycle

  • Who configures, approves and may change the project
  • Version control and where the archive is kept
  • Commissioning evidence and validation records required
  • Spares strategy and expected machine lifetime
Related technologies

PNOZmulti 2 sits in the architecture

Sensors and command devices feed the controller; the controller evaluates and drives the safe outputs. Diagnostics can be shared with the standard control system without that system becoming part of the safety function.

Guard switches and E-STOP devices
PSENopt II, PSENscan and PSENradar
Motion-monitoring modules
Safe outputs to contactors and drives
PITreader as permission input
PSS 4000 for plant-scale architectures
Pilz safety laser scanners connected in series to a PNOZmulti 2 controller