PMCprotego Safe Motion
A safety card within the drive, so the motion safety functions are evaluated where the motion is generated. The manufacturer states the drive achieves up to PL e of EN ISO 13849-1 with common motor feedback systems and fieldbuses.
- Drive-integrated safety card rather than an external monitor
- Up to performance level PL e, and SIL 3, per manufacturer product information
- Reaction is local to the drive, without external wiring loops
- Confirm the current PMC family and drive compatibility for the project