NOVUS · Refrigeration & HVAC Control

N323

Three-output ON/OFF temperature controller for applications requiring three independently configured setpoints/control-alarm functions.

NOVUS N323
RoleThree-output heating and cooling temperature controller
CategoryProcess Control & Indication · Electronic Thermostats / Controllers
ApplicationHeating / refrigeration
SelectionSensor · outputs · sequence
Engineering position

Three-output heating and cooling temperature controller for heating, refrigeration or HVAC sequences

The controller coordinates temperature or humidity measurement with compressor, heating, defrost, fan, alarm or auxiliary functions. Output count alone is not sufficient for selection; sensor version, control sequence, electrical ratings, supply and communication options must also match the refrigeration or HVAC design. Three-output ON/OFF temperature controller for applications requiring three independently configured setpoints/control-alarm functions.

Heating or refrigeration actionConfirm direct/reverse action, hysteresis and load ratings for the heating or cooling duty.
Setpoint and alarm configurationDefine independent setpoints, alarms and auxiliary output functions before commissioning.
Panel control integrationMatch sensor version, relay allocation, supply and optional communication to the panel schematic.
Current product position: Current N321/N322/N323 documentation treats the sensor input as an ordered product version—NTC, Pt100 or J/K/T—not as one universal input.
System role

N323 signal and system architecture

The architecture separates the field/process interface, the NOVUS function and the downstream control or information path. Exact electrical interfaces, protocol roles and accessories remain model-dependent.

01Temperature sensor
02N323
03Relay output(s)
04Compressor / heater / fan
05Controlled space
Use the current NOVUS product page, manual and exact order code as the final authority for numeric ratings, approvals, firmware-dependent functions and supplied accessories.
Application scope

N323 application environments

These application classes indicate the engineering context. Final selection still depends on the exact range, I/O, communication, installation and performance requirements.

01

Cold rooms

For cold rooms, confirm the sensor version, output allocation and control sequence before assigning compressor, heating, defrost, fan or alarm functions.

02

Refrigerated cabinets

For refrigerated cabinets, confirm the sensor version, output allocation and control sequence before assigning compressor, heating, defrost, fan or alarm functions.

03

HVAC temperature loops

For hvac temperature loops, confirm the sensor version, output allocation and control sequence before assigning compressor, heating, defrost, fan or alarm functions.

Technical data

Technical data and model boundaries

The table is a selection summary, not a substitute for the current NOVUS manual or ordering information. Product families and optional versions can differ in input, output, communication, supply and approvals.

Ordered sensor versionsNTC, Pt100, or J/K/T thermocouple version
ControlON/OFF heating or cooling with adjustable hysteresis
Outputs3 outputs; exact relay arrangement depends on model
CommunicationOptional RS485 Modbus RTU on supported versions
Sampling1.5 readings per second
Supply100–240 Vac/dc; low-voltage version available
Panel75 × 33 × 75 mm; IP65 front
Documentation & engineering inputs

Current NOVUS documentation and application data

Use the manufacturer page for the current orderable configuration, then provide the application information below so Primionics can review technical fit, accessories and commercial scope.

Measured variablesTemperature only or combined temperature/relative humidity.
Controlled functionsCompressor, heating, defrost, fan, lighting, alarm and timer requirements.
Output ratingsLoad type, voltage/current and whether external contactors/relays are required.
InstallationPanel format, supply, sensor location and environmental conditions.
ConnectivityStandalone, optional RS485 or connected/remote-management architecture.
Commercial scopeQuantity, sensors/accessories, commissioning support and delivery target.