RHT-DM

Duct/extended-probe temperature and relative-humidity transmitter for measurement inside air-handling ducts or through wall penetrations.

NOVUS RHT-DM
VariablesTemperature + RH
RoleDuct-mounted temperature and humidity transmitter
CategorySensing, Conditioning & Transmitters / Data Acquisition
ScopeEnvironmental measurement
Engineering position

Duct-mounted temperature and humidity transmitter for environmental measurement

The product measures or communicates environmental temperature and relative humidity for building, laboratory, storage and controlled-environment systems. These products support environmental-condition monitoring; airborne-particle classification, continuous particle counting and HEPA-filter integrity testing require separate contamination-control instrumentation. Duct/extended-probe temperature and relative-humidity transmitter for measurement inside air-handling ducts or through wall penetrations.

Temperature measurementConfirm measurement range, mounting position, response requirements and calibration expectations.
Relative-humidity measurementConfirm RH range, condensation exposure, calibration expectations and installation airflow.
System integrationSelect analogue, RS485, wireless or cloud integration according to the data consumer and network architecture.
Current product position: Current NOVUS information positions RHT-WM and RHT-DM as temperature/RH transmitters for wall and duct/extended-probe installation, with configuration through SigNow.
System role

RHT-DM signal and system architecture

The architecture separates the field/process interface, the NOVUS function and the downstream control or information path. Exact electrical interfaces, protocol roles and accessories remain model-dependent.

01Duct air stream
02RHT-DM probe
034–20 mA transmission
04BMS / logger / PLC
05HVAC monitoring / control
Use the current NOVUS product page, manual and exact order code as the final authority for numeric ratings, approvals, firmware-dependent functions and supplied accessories.
Application scope

RHT-DM application environments

These application classes indicate the engineering context. Final selection still depends on the exact range, I/O, communication, installation and performance requirements.

01

HVAC air monitoring

In hvac air monitoring, place and specify the measurement point according to airflow, condensation risk, calibration requirements and the required analogue, RS485 or wireless information path.

02

Controlled storage

In controlled storage, place and specify the measurement point according to airflow, condensation risk, calibration requirements and the required analogue, RS485 or wireless information path.

03

Laboratories and cleanroom environmental monitoring

In laboratories and cleanroom environmental monitoring, place and specify the measurement point according to airflow, condensation risk, calibration requirements and the required analogue, RS485 or wireless information path.

Technical data

Technical data and model boundaries

The table is a selection summary, not a substitute for the current NOVUS manual or ordering information. Product families and optional versions can differ in input, output, communication, supply and approvals.

MountingDuct or wall pass-through
Temperature range−40 to 120 °C
Probe lengths150 or 250 mm
OutputsIsolated 4–20 mA, 2-wire loop powered
ConfigurationSigNow through TxConfig-USB
HousingIP65; sensor capsule IP40
Documentation & engineering inputs

Current NOVUS documentation and application data

Use the manufacturer page for the current orderable configuration, then provide the application information below so Primionics can review technical fit, accessories and commercial scope.

Measured variablesTemperature, relative humidity and any required psychrometric values.
Measurement locationWall, duct, room, probe position, airflow and condensation exposure.
Data interface4–20 mA, 0–10 V, RS485, wireless network or cloud/SCADA integration.
Accuracy & calibrationRequired uncertainty, calibration points, traceability and re-calibration interval.
Compliance scopeRecord retention/validation needs; separate particle/HEPA requirements if applicable.
Commercial scopeNumber of points, gateways, accessories, software and commissioning support.