Process measurement
For process measurement, match the process variable and range to the transmitter/indicator input, output standard, mounting and receiving controller or logger.
Head-mounted isolated HART temperature transmitter for applications requiring galvanic isolation, 4–20 mA transmission and HART device access.

The product conditions or presents a field measurement before it reaches a controller, logger, PLC or operator. Selection is driven by sensor or process variable, measurement range, output standard, isolation, mounting, process connection and environmental conditions. Head-mounted isolated HART temperature transmitter for applications requiring galvanic isolation, 4–20 mA transmission and HART device access.
The architecture separates the field/process interface, the NOVUS function and the downstream control or information path. Exact electrical interfaces, protocol roles and accessories remain model-dependent.
These application classes indicate the engineering context. Final selection still depends on the exact range, I/O, communication, installation and performance requirements.
For process measurement, match the process variable and range to the transmitter/indicator input, output standard, mounting and receiving controller or logger.
For panel instrumentation, match the process variable and range to the transmitter/indicator input, output standard, mounting and receiving controller or logger.
For data-acquisition inputs, match the process variable and range to the transmitter/indicator input, output standard, mounting and receiving controller or logger.
The table is a selection summary, not a substitute for the current NOVUS manual or ordering information. Product families and optional versions can differ in input, output, communication, supply and approvals.
| Inputs | J, K, T, N, R, S, B, E, Pt100, Pt1000, NTC and 0–50 mV |
|---|---|
| Output | 4–20 mA with HART 7; compatible with HART 5 |
| Isolation | 1.5 kVrms input to output |
| Supply | 8.5–36 Vdc, loop powered |
| Mounting | Head mount |
| Configuration | HART-compatible configuration or NOVUS interface according to documentation |
Use role, range, I/O, installation and communication requirements to distinguish nearby products. Similar naming does not imply interchangeable electrical or functional capability.
Head-mounted isolated HART temperature transmitter for applications requiring galvanic isolation, 4–20 mA transmission and HART device access.
Inputs: J, K, T, N, R, S, B, E, Pt100, Pt1000, NTC and 0–50 mVhead-mount temperature transmitterHead-mounted loop-powered temperature transmitter for converting supported sensor inputs into an industrial 4–20 mA signal.
Mounting: Sensor-head mountDIN-rail temperature transmitterDIN-rail temperature transmitter family for panel-mounted signal conditioning; exact TxRail variant must be selected from input, output and configuration requirements.
Inputs: J, K, T, E, N, R, S thermocouples; Pt100; 0–50 mVUse the manufacturer page for the current orderable configuration, then provide the application information below so Primionics can review technical fit, accessories and commercial scope.