BBT 143 Blow-By Oil Content Measurement System
Compact measurement system for determining oil-droplet content in crankcase blow-by gas at engine test rigs, combining gravimetric sampling with fast optical concentration measurement.
Model Overview
| Model | System role | Primary measurements | Standards / application fit |
|---|---|---|---|
| BBT 143 | Blow-by oil-content measurement system | Gravimetric oil-mass determination with time-resolved optical concentration monitoring | Engine blow-by measurement and oil-mist separator evaluation |
Key Features
Combined measurement principles
Uses gravimetric measurement for accuracy and optical photometry for high time resolution.
Full-flow capability
Measures blow-by streams at flow rates up to 300 L/min.
Differential-pressure compensation
Optional compensation supports representative gravimetric sampling.
Rapid inline response
Optical measurement tracks transient changes in oil-mist concentration.
Engine-test integration
The compact system is designed for connection to engine development test stands.
Separator performance evaluation
Supports assessment of oil-mist separator behaviour under realistic blow-by conditions.
Technical Specifications
| Parameter | Unit | Value / Description |
|---|---|---|
| PERFORMANCE | ||
| Maximum aerosol flow | L/min | 300 |
| Measurement principles | — | Gravimetric sampling and optical inline concentration measurement |
| Measured medium | — | Oil-droplet aerosol in crankcase blow-by gas |
| SYSTEM | ||
| Compressed-air supply | bar | 6 |
| Optional components | — | Differential-pressure compensation and gravimetric filter media |
| Integration | — | Engine test stand and separator-development workflows |
Values shown are based on the standard system configuration. Confirm the final test method, specimen fixtures, instrumentation, utilities and calibration scope before order placement.
Applications
Engine blow-by oil measurement
Determination of oil content in crankcase gases during engine testing.
Oil-mist separator evaluation
Comparison of separator performance at representative flow conditions.
Transient oil-mist monitoring
Time-resolved concentration measurement during changing engine states.
Gravimetric reference measurement
Reproducible oil-mass determination for test-bench correlation.