Particle, Filtration & Air Quality Test Technologies
Measurement and testing instruments for cleanroom qualification, HEPA/ULPA filter integrity testing, aerosol characterization, and air quality analysis, supported by Primionics.
Technology Partner
Topas GmbH
Since more than three decades the name Topas stands for high-quality products and innovative efforts in the field of particle, aerosol and filter testing technology — developed, designed and made in Germany. Both domestic customers and customers abroad have taken benefit from the ideas and experiences of Topas GmbH as a developer and manufacturer of equipment for the generation, measurement and dilution of airborne particles (aerosols) and complex test systems for various air filters, filter media and separators.
The Topas company / customer philosophy enables a fast response to changes on the current market and the realisation of customer demands. Their own research and development as well as a close cooperation with universities and research institutions has steadily expanded the company know-how leading to ongoing new solutions for Topas customers. Keeping close contact to market demands Topas has been widening its product range over the years and continuously focuses its efforts on product optimisation and quality improvement.
Aerosol generation from powders or liquids for test, calibration, and qualification applications.
Aerosol dilution, drying, neutralisation, and sampling for controlled measurement conditions.
Measuring particle size and concentration, pore size measurement, and spectrometry.
Particle analysis software and test system control for structured protocol output.
Complete test systems for filter mediums, filter elements, and air filtration devices.
Application-specific instrument configurations and bespoke test system development.
Aerosol Generation, Measurement, and Filter Integrity Testing
These instruments support the key measurement steps used in cleanroom validation and HEPA/ULPA filter integrity testing. The system combines aerosol generation, controlled dilution, particle measurement, and filter scanning to perform qualification measurements aligned with standards such as ISO 14644 and EN 1822.
Cleanroom Qualification Instruments
Aerosol Generation
Atomizer — Mobile, Remote & Battery
Mobile brushless-compressor atomizer with remote capability and optional battery for fully cordless operation. The go-to generator for cleanroom HEPA acceptance per ISO 14644-3 and safety cabinet testing per DIN EN 12469.
Conditioning
Dilution System — 1:100 Mobile Controlled
Mobile controlled static dilution (1:100) at 28.3 L/min with digital status communication and battery operation. For cleanroom acceptance testing per EN ISO 14644-3 and VDI 2083 without fixed compressed air.
Aerosol Generation
Condensation Fog Generator
Generates dense visible fog for airflow visualisation per ISO 14644-3. Stable fine-droplet fog for smoke studies, airflow pattern testing, and cleanroom qualification.
Conditioning
Rectangular Sampling Probe — 28.3 L/min
Rectangular scanning probe for filter leakage and integrity testing per ISO 14644-3 at 28.3 L/min. Standard companion probe for the CPA341 / DIL 544 / ATM 228 cleanroom acceptance measurement set.
Particle Measurement
Cleanroom Particle Counter
Laser cleanroom particle counter measuring 0.3–10 µm particles at 28.3 L/min. Designed for ISO 14644 cleanroom validation, filter efficiency testing, and contamination monitoring in controlled environments.
Test SystemHEPA/ULPA Filter Scan System — Automated
Fully automated scan test for HEPA and ULPA integrity per EN 1822-4/5 and ISO 29463. Supports up to 1220 × 1830 mm.
Request Quote →
Test SystemHEPA/ULPA Filter Scan System — Manual
Manual probe guidance for HEPA/ULPA integrity testing per EN 1822-4/5 and ISO 29463.
Request Quote →
Test SystemFilter Media Test System — Cleanable Media
Tests cleanable flat filter media per VDI 3926 and ISO 11057.
Request Quote →
Test SystemFilter Media Test System — ISO 16890
Fractional efficiency and pressure drop per ISO 16890, EN 779, ASHRAE 52.2.
Request Quote →
Test SystemGeneral Air Filter Test System
Tests ventilation filters per ISO 16890, EN 779, and ASHRAE 52.2 with EUROVENT classification.
Request Quote →
Test SystemAir Intake Filter Test System
Automotive and industrial air intake filter testing per ISO 5011.
Request Quote →
Test SystemCabin Air Filter — Particulate Test
Particulate filtration per DIN 71460-1 and ISO 11155-1.
Request Quote →
Test SystemOil Mist Separator Test System
Tests oil mist separators for pressure drop, gravimetric and fractional efficiency.
Request Quote →
Test SystemPore Size Measurement System
Pore size distribution, bubble point, and gas permeability via capillary flow porometry.
Request Quote →
GenerationAtomizer — Mobile, Remote & Battery
Mobile brushless atomizer with battery option for cordless HEPA acceptance per ISO 14644-3.
Request Quote →
GenerationCondensation Fog Generator
Dense visible fog for airflow visualisation per ISO 14644-3.
Request Quote →
GenerationAtomizer — Base Model
Standard lab atomizer for DEHS, salt, or PAO aerosols per VDI 3491.
Request Quote →
GenerationAtomizer — Mobile, Integrated Compressor
Self-contained with integrated compressor. No external air required. For cleanroom acceptance.
Request Quote →
GenerationSolid Aerosol Generator — Standard
Toothed belt dosing for ASHRAE dust and A2 fine test dust with high output constancy.
Request Quote →
GenerationCondensation Aerosol Generator — Monodisperse
Stable monodisperse aerosols with independently adjustable size and concentration for calibration.
Request Quote →
ConditioningDilution System — 1:100 Mobile Controlled
Battery-operated 1:100 mobile dilution with digital status. No compressed air needed.
Request Quote →
ConditioningDilution System — 1:100 Standard
Workhorse 1:100 dilution at 28.3 L/min for cleanroom acceptance per EN ISO 14644-3.
Request Quote →
ConditioningRectangular Sampling Probe — 28.3 L/min
Standard companion probe for DIL 544 / ATM 228 cleanroom acceptance sets.
Request Quote →
ConditioningDiffusion Dryer — High Model
Silica gel dryer removing moisture without affecting particle size.
Request Quote →
ConditioningElectrostatic Aerosol Neutralizer
Source-free ion generation for Boltzmann charge equilibrium. No radioactive material.
Request Quote →
ConditioningConditioning Cabinet — ISO 16890-4
IPA vapour conditioning for discharging air filters per ISO 16890-4.
Request Quote →
MeasurementLaser Aerosol Spectrometer
High-resolution OPC 0.2–40 µm for filter efficiency, aerosol characterisation, cleanroom monitoring.
Request Quote →
MeasurementDual-Laser Aerosol Spectrometer
Dual laser wavelengths for exceptional accuracy 0.2–40 µm with remote app control.
Request Quote →
MeasurementPore Size Measurement System
Capillary flow porometry for pore size distribution, bubble point, and permeability.
Request Quote →
SoftwareCleanroom Qualification Software
ISO 14644, DIN 2083, EU GMP cleanroom qualification with automated protocol output.
Request Quote →
SoftwareParticle Analysis Software
Control, logging, and analysis for LAP spectrometers. ISO 9276-1/2 distributions.
Request Quote →
AccessoryTest Substance — DEHS
Standard liquid aerosol substance per VDI 3491 and ISO 14644. Colourless, odourless, chemically stable.
Request Quote →
AccessoryFog Fluid — TopFog
Polyhydric alcohol fog fluid for CFG 291. Flow visualisation per ISO 14644-3.
Request Quote →
AccessorySilica Gel — Indicating
Replacement silica gel with colour indicator for DDU 570 dryers.
Request Quote →Industries & Applications
Topas instruments are used across a wide range of industries where cleanroom qualification, filtration performance, and aerosol measurement are critical to product quality and regulatory compliance.
Pharma & Biotech
Cleanroom qualification, HEPA integrity testing, environmental monitoring, and GMP compliance workflows.
Semiconductor & Electronics
ISO Class 1–6 cleanroom testing, particle monitoring, and contamination control for fab environments.
Medical Devices & Hospitals
Operating theatre qualification per DIN 1946-4, cleanroom certification, and medical filter testing.
Automotive & EV
Cabin air filter testing per ISO 11155, air intake filter testing, and GPF/DPF production QC.
Aerospace
HEPA filter integrity testing, cabin air filtration qualification, and clean assembly environment testing.
HVAC & Air Quality
General ventilation filter testing per ISO 16890, EN 779, and ASHRAE 52.2 with EUROVENT classification.
Energy & Gas Turbines
Gas turbine intake filter testing per ISO 29461 under controlled temperature and humidity conditions.
Research & Testing Labs
Aerosol science, filter media characterisation, pore size analysis, and instrument calibration services.
Technical Access to Filtration & Cleanroom Test Technologies
Filtration and cleanroom testing often require multiple instruments working together across the measurement chain. Primionics helps engineering teams evaluate the application, testing standards, and measurement workflow to identify the appropriate Topas technologies for their projects.
Application-Led Selection
We help identify the right instrument combination for your test standard, workflow, and operating environment.
India-Facing Interface
Commercial and technical coordination through Primionics for qualification, quoting, and project support.
Standards Knowledge
ISO 14644, EN 1822, ISO 16890, VDI 3926, ASHRAE 52.2 — we understand the standards your lab needs to meet.
Complete Measurement Chain
From aerosol generation through conditioning, sampling, and measurement — we help configure the full system.
Datasheet & SOP Support
Technical documentation, instrument datasheets, and application guidance available through Primionics.
Project-Driven Engagement
Aligned for labs, filter manufacturers, cleanroom contractors, and qualification service providers.
Start the Conversation
Discuss Your Testing Requirement