Home Precision Environment Aerosol Sensor Calibration Systems AFC 135 Aerosol Sensor Test & Calibration System
AFC 135 Aerosol Sensor Test & Calibration System product image thumbnail
AFC 135 Aerosol Sensor Test & Calibration System workflow diagram thumbnail
AFC 135 Aerosol Sensor Test & Calibration System application overview thumbnail
Topas GmbH Aerosol Sensor Test & Calibration Systems

AFC 135 Aerosol Sensor Test & Calibration System

Flexible test platform for development, testing and calibration of active or passive PMx and PNx aerosol sensors using stable, defined solid or droplet aerosols over a wide volume-flow range.

Test flow
0.8–450 m³/h
Test concentration
5–1,000 µg/m³ at 100 m³/h
Sensor types
Active / passive PMx and PNx
Reference
Customer-specific particle instrumentation
PM sensors PN sensors Sensor calibration Solid / droplet aerosols Wide flow range
Customer-specific sensor methods Reference-instrument calibration

Model Overview

Model System role Primary measurements Standards / application fit
AFC 135 Aerosol-sensor development and calibration system Defined aerosol exposure, reference measurement and sensor-response evaluation PMx/PNx sensor development, production quality assurance and ageing studies

Key Features

Stable defined aerosol exposure

Creates controlled aerosol concentrations at variable volume-flow rates for repeatable sensor evaluation.

Solid and droplet aerosols

Supports different particle types for PM and PN sensor response studies.

Wide flow range

Optional measuring sections cover approximately 0.8–40 m³/h and 40–450 m³/h.

Flexible sensor integration

Active and passive sensors, probes, flat media and other devices can be mounted with suitable fixtures.

Reference instrumentation

Topas or external particle instruments can be integrated for traceable comparative measurement.

Customer-specific configuration

The platform can be adapted for development, production calibration and ageing investigations.

Technical Specifications

Parameter Unit Value / Description
TEST RANGE
Test flow rate m³/h 0.8–450
Test concentration µg/m³ 5–1,000 at 100 m³/h
Maximum specimen pressure drop Pa 10,000 at 450 m³/h
Duct diameter mm 150
SYSTEM
Aerosol generation Controlled generator for solid and/or droplet aerosols
Reference measurement Customer-specific, for example LAP 323 aerosol spectrometer
Sensors Differential pressure, temperature, relative humidity and absolute pressure
Power supply 400 VAC, 25 A

Values shown are based on the standard system configuration. Confirm the final test method, specimen fixtures, instrumentation, utilities and calibration scope before order placement.

Applications

PMx and PNx sensor development

Characterisation of sensor response across concentration, particle type and airflow.

Sensor calibration and QA

Repeatable comparative calibration and end-of-line quality assurance.

Sensor ageing studies

Controlled exposure for monitoring drift and ageing behaviour.

Aerosol fundamentals

Flexible integration of sensors and reference instruments for experimental investigations.