NOVUS · Environmental & Controlled-Environment Monitoring

Climate Air+

Scalable wireless temperature/RH monitoring system built around RHT Air+ sensors and the AirGate Air+ gateway for distributed critical environments.

NOVUS Climate Air+
ArchitectureSensor + gateway + software
WirelessLoRa
ScaleUp to 32 sensors/gateway
ScopeSystem, not a single sensor
Engineering position

Wireless temperature and humidity monitoring system for environmental measurement

The product measures or communicates environmental temperature and relative humidity for building, laboratory, storage and controlled-environment systems. These products support environmental-condition monitoring; airborne-particle classification, continuous particle counting and HEPA-filter integrity testing require separate contamination-control instrumentation. Scalable wireless temperature/RH monitoring system built around RHT Air+ sensors and the AirGate Air+ gateway for distributed critical environments.

Temperature measurementConfirm measurement range, mounting position, response requirements and calibration expectations.
Relative-humidity measurementConfirm RH range, condensation exposure, calibration expectations and installation airflow.
System integrationSelect analogue, RS485, wireless or cloud integration according to the data consumer and network architecture.
Current product position: Current Climate Air+ is a system rather than a single sensor: RHT Air+ wireless sensors connect through AirGate Air+, with local record buffering and open northbound protocols.
System role

Climate Air+ signal and system architecture

The architecture separates the field/process interface, the NOVUS function and the downstream control or information path. Exact electrical interfaces, protocol roles and accessories remain model-dependent.

01RHT Air+ sensors
02LoRa wireless network
03AirGate Air+
04MQTT / Modbus TCP / NOVUS Cloud
05Monitoring / reports / alarms
Use the current NOVUS product page, manual and exact order code as the final authority for numeric ratings, approvals, firmware-dependent functions and supplied accessories.
Application scope

Climate Air+ application environments

These application classes indicate the engineering context. Final selection still depends on the exact range, I/O, communication, installation and performance requirements.

01

HVAC air monitoring

In hvac air monitoring, place and specify the measurement point according to airflow, condensation risk, calibration requirements and the required analogue, RS485 or wireless information path.

02

Controlled storage

In controlled storage, place and specify the measurement point according to airflow, condensation risk, calibration requirements and the required analogue, RS485 or wireless information path.

03

Laboratories and cleanroom environmental monitoring

In laboratories and cleanroom environmental monitoring, place and specify the measurement point according to airflow, condensation risk, calibration requirements and the required analogue, RS485 or wireless information path.

Technical data

Technical data and model boundaries

The table is a selection summary, not a substitute for the current NOVUS manual or ordering information. Product families and optional versions can differ in input, output, communication, supply and approvals.

System componentsRHT Air+ wireless sensors and AirGate Air+ gateway
Wireless layerLoRa with long-range communication
Gateway capacityUp to 32 RHT Air+ sensors
Sensor memory16,000 records per RHT Air+
Gateway bufferUp to 1,024,000 records
IntegrationMQTT, NTP and Modbus TCP; NOVUS Cloud integration
Compliance supportNOVUS documents FDA 21 CFR Part 11 support for the solution
Documentation & engineering inputs

Current NOVUS documentation and application data

Use the manufacturer page for the current orderable configuration, then provide the application information below so Primionics can review technical fit, accessories and commercial scope.

Measured variablesTemperature, relative humidity and any required psychrometric values.
Measurement locationWall, duct, room, probe position, airflow and condensation exposure.
Data interface4–20 mA, 0–10 V, RS485, wireless network or cloud/SCADA integration.
Accuracy & calibrationRequired uncertainty, calibration points, traceability and re-calibration interval.
Compliance scopeRecord retention/validation needs; separate particle/HEPA requirements if applicable.
Commercial scopeNumber of points, gateways, accessories, software and commissioning support.