Continuous visibility
Remote particle sensors, environmental channels, alarms and historical trends reveal conditions that periodic spot measurements can miss.
Primionics supplies continuous cleanroom monitoring, portable and remote particle counters, airflow instruments, aerosol generators, HEPA/ULPA filter-test systems and environmental data platforms in India. Applications include classification, routine monitoring, recovery studies, HVAC commissioning, filter scanning and contamination investigations.
Remote particle sensors, environmental channels, alarms and historical trends reveal conditions that periodic spot measurements can miss.
Sample location, tubing, flow rate, transport loss and room operating state directly influence particle-counting results.
HEPA/ULPA systems require controlled aerosol challenge, leakage detection, airflow verification and documented test conditions.
Remote particle sensors, monitoring software, configurable alarms, trend review and integration of temperature, humidity and pressure channels.
Portable and handheld particle counters for classification, troubleshooting, recovery studies and routine checks.
Air velocity, volume flow, differential pressure, temperature and humidity measurement for cleanrooms and HVAC systems.
Aerosol generators, photometers, dilution and conditioning technologies, filter scanning and dedicated filter-test systems.
Fixed remote particle sensors, centralized acquisition, configurable alarms, event review and time-stamped historical records.
Mobile instruments for cleanroom classification, troubleshooting, recovery studies, filter work and location-specific investigations.
Anemometers, micromanometers and environmental instruments for velocity, volume flow, pressure, temperature and humidity.
Controlled challenge-aerosol generation and detection for HEPA/ULPA integrity testing, leakage localization and system verification.
Platforms for filter media, filter elements, high-flow filters and production-quality testing across defined test conditions.
Consolidated views, alarm notifications, trends, reports and interfaces for facility or environmental monitoring systems.
Critical locations, particle sizes, sample flow, tubing length and transport loss matched to the room and monitoring objective.
Time-stamped particle and environmental data with alert levels, delays, user access, event review and retained trends.
Controlled aerosol generation, dilution, photometer response, scan method and airflow measurement for HEPA/ULPA leakage testing.
Calibration status, test conditions and structured records for ISO 14644, EN 1822, ISO 29463 and site-specific procedures where applicable.